Kunshan WonderTek Technology Co.,Ltd.
 
 
Powerline Ethernet Bridge Phoneline Ethernet Bridge Coaxial Ethernet Bridge BPL Powerline Ethernet Bridge Smart Grid Industry Wi-Fi/PoE Switch PLC-Blocking Filter&Coupler PLC-Access control system
WD-1201M-DIN-DC12V

   Industrial Powerline Ethernet Bridge

               Model: WD-1201M-DIN-DC12V

 

System drawing and field wiring

1、Control computer
2、Switch or router
3、Powerline Ethernet Bridge(WD-1201M-DIN-DC12V)
4、Conductor rail/cable
5、Peripheral equipment
6、DC12V 1Am
7、AC85-265V


Technical parameter


Model  WD-1201M-DIN-DC12V     
Interface  1*LAN 10/100/1000Base-TX self adaption RJ45,1*AC power interface MDI/MDX suppor  1*AC+PLC ,   2*DC12V   
LED display light  Ethernet, PLC link ,power 
Transfer frequency  2-68Mhz
Protocol(PHY)  IEEE802.3,IEEE802.3x, IEEE802.3u HomePlugAV2
Security  128-AES
Number of each group  Up to 32
installation  Rail  TS35
Protection level  IP40
Transfer rate(PHY)  1200Mbps
Modulation  OFDM
Effective transfer rate  TCP/IP  550Mbps    
Manageability
 
 Remote Firmware update,support TR-069(optional)
 802.1D Ethernet Bridge
 802.1Q VLAN
 Quality of Service(QoS)
 IGMO(IPv4)Snooping&MLD(IPv6)Snooping
Voltage range  AC 90V-265V  
Output  DC12V 1A
Operating temperature  -40℃-70℃
Size  120*90*45mm(L×W×H)
Weight  0.65kg
Operating environment  Operating humidity:10%-85% (no condense)
 Storage humidity: 5%-90%(no condense)
Certification  FCC、CE class B, RoHS
 

Features


(1) Packet loss:≤0.1%(100M,load 70%).
(2) Support 7*24 hours all weather operation.
(3) Hardware watch dog function.
(4) PING≤20MS.

Immunity of ESD
The testing voltage which the device should be beared: ±6kV direct Discharge, ±8kV air discharge. Discharge number in Each sensitive testing point: Plus-n-Minus 10 times each, Every time the discharge interval is 1 s, according to B/T 17626.2-2006.

Immunity of electrical fast transient impulse group(Commonmode)
The testing voltage which the device should be beared:
between the power supply voltage port and ground: ±2.0kV;
between signal circuit and ground: ±1.0kV;
repetition frequency: 5KHz, test duration: 1 min/ time;
testing times: Plus-n-Minus 5 times each. According to GB/T 17626.4-2008.

Anti interference of surge impact
The testing voltage which the device should be beared: ±2kV;
The interval of continuous impulses: 1min/time;
Test number: Plus-n-Minus 5 times each. According to GB/T 17626.5-2008.(protection: all models protection and varistor series of
discharge tube type)

Anti- vibration
Meet the demand of MX3 in TB1433(0-200Hz,2g acceleration, maximum amplitude 7mm), interface with no loose, device with no Sealing off and drop in the test


State analysis


 LED Indicator description
Ethernet  The connection between products is not established
PLC    Whether the device is connected to other Ethernet devices
Power  Check whether the device is powered on
 Blinking indicates that the device is transmitting data


Indicator description

 
Item Status Description
   On  Connect the network equipment successfully
 Off  Connect the network equipment unsuccessfully
 Blinking  Begin connecting the data transmission
 On  Connect the similar equipment successfully
 Off  Connect the similar equipment unsuccessfully
 Blinking  Begin connecting the data transmission
 On  Power on
 Off  Power off
                                                                         
 
Share:

Contact us

0512-83670078

15962529299
Available Time: 9:00-20:00 GMT+8
Learn more